Three-phase circuit parameters meter#

block

Block appearance in REPEAT VISION#

 The Three-phase circuit parameters meter unit is designed to obtain the following parameters of three-phase circuits:

  • instantaneous value of phase A voltage;

  • instantaneous value of phase B voltage;

  • instantaneous value of phase C voltage;

  • effective value of phase A voltage;

  • effective value of phase B voltage;

  • effective value of phase C voltage;

  • instantaneous value of phase A current;

  • instantaneous value of phase B current;

  • instantaneous value of phase C current;

  • instantaneous value of current in the neutral conductor;

  • effective value of phase A current;

  • effective value of phase B current;

  • effective value of phase C current;

  • effective value of current in the neutral conductor;

  • instantaneous active power;

  • instantaneous reactive power;

  • average active power;

  • average reactive power;

  • average apparent power;

  • power factor.

 The internal resistance between the input and output terminals of each phase is zero. The internal resistance between the terminals of different phases and between any phase terminal and the neutral terminal is absent (equal to infinity).

 The block eliminates the need to calculate the effective values ​​of currents and voltages, as well as average power values. This option is set in the parameters and can be used to save computing resources and speed up the simulation process.

 The block allows calculation of parameters for both a three-wire, three-phase system and a four-wire system. Adding a ground potential (input and output terminals) is accomplished by selecting the appropriate option in the parameters.

 The parameters are calculated as follows:

  • __The effective values ​​of voltage or current of each phase __ are determined by the formula (1):

(1)#\[X_{n.rms}=\frac{1}{T} \cdot \sqrt{\int^T_0x^2_ndt}\]

where:

 \(x\) – instantaneous value of the measured parameter (voltage u or phase current i);

 \(n\) – phase designation: A, B, C;

 \(T\) – measurement period, which is determined by the formula (2):

(2)#\[T=\frac{1}{f}\]

where \(f\) is the base frequency, [Hz].

  • Instantaneous values ​​of phase voltages are determined depending on the configuration of the block terminals:

    • linear voltage values ​​are determined by the formulas (3):

    (3)#\[\begin{split}u_{AB}=\phi(A)-\phi(B);\\u_{BC}=\phi(B)-\phi(C);\\u_{CA}=\phi(C)-\phi(A)\end{split}\]
    • in the presence of a neutral conductor, the instantaneous voltage values ​​are determined as the potential difference between the terminal of the corresponding phase and the neutral terminal (4) :

    (4)#\[\begin{split}u_{A}=\phi(A) - \phi(N);\\u_{B}=\phi(B) - \phi(N);\\u_{C}=\phi(C) - \phi(N)\end{split}\]
    • in the absence of a neutral conductor, phase voltages are calculated based on linear values ​​using the formulas (5):

    (5)#\[\begin{split}u_{A}=\frac{U_{AB}-U_{CA}}{3};\\u_{B}=\frac{U_{BC}-U_{AB}}{3};\\u_{C}=\frac{U_{CA}-U_{BC}}{3}\end{split}\]
  • Instantaneous values ​​of phase currents are defined as the magnitude of the current passing through the input and output terminals of the corresponding phases.

  • Instantaneous power values are determined by the formulas (6):

(6)#\[\begin{split}p=u_A \cdot i_A + u_B \cdot i_B+ u_C \cdot i_C;\\q=\frac{1}{\sqrt{3}}\cdot (u_{AB} \cdot i_C + u_{BC} \cdot i_A + u_{CA} \cdot i_B)\end{split}\]
  • Average power values are determined based on the instantaneous power values ​​(7):

(7)#\[\begin{split}P=\frac{1}{T}\cdot \int^T_0pdt,\\S=\sqrt{\frac{1}{T}\cdot \int^T_0(p^2 + q^2)dt},\\Q=\sqrt{S^2-P^2}\end{split}\]
  • Power factor is determined by the formula (8) :

(8)#\[K_M=\frac{P}{S}\]

1.  Properties#

Property

Default Value

Description

Units of measurement

Base frequency

50

Determines the period for calculating root mean square and average values

Hz

Initial values of calculated values: \(U_{A.rms}\), \(U_{B.rms}\), \(U_{C.rms}\), \(I_{A.rms}\), \(I_{B.rms}\), \(I_{C.rms}\), \(P\), \(S\)

0, 0, 0, 0, 0, 0, 0, 0

Allows you to maintain the initial value at a given level during the calculation of average and root mean square values ​​at the beginning of the simulation

–

Calculation of RMS voltage and current values

On

–

–

Calculation of average power values

On

–

–

Enable neutral wire

Off

–

–

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

A+

Input

Phase A input terminal

–

Electronics

B+

Input

Phase B input terminal

–

Electronics

C+

Input

Phase C input terminal

–

Electronics

N+

Input

The neutral conductor input terminal is available when Enable neutral wire is On

–

Electronics

A–

Output

Phase A output terminal

–

Electronics

B–

Output

Phase B output terminal

–

Electronics

C–

Output

Phase C output terminal

–

Electronics

N-

Output

The neutral conductor output terminal is available when Enable neutral wire is On

–

Electronics