Check Valve (IH)#

block

Block appearance in REPEAT VISION#

 The Check valve (IH) unit is a model of a check valve with free flow from the inlet port to the outlet port and limited in the opposite direction.

 The Opening pressure specification property allows the user to select pressure control points:

  • when the DifPressure value is selected, the valve controls the pressure difference between the ports of the block;

  • when selecting the value Pressure at port A - the pressure value in the inlet port.

 When the valve operates in the differential pressure control mode between ports, the valve begins to open and fully opens when the differential pressure thresholds set by the user between ports are exceeded – the corresponding values ​​are configured through the block properties:

 Similarly, when the valve operates in the pressure control mode in port A, the user sets the properties:

 The check valve supports 3 types of parameterization of its flow characteristics:

  • The open area of ​​the valve depends linearly on the magnitude of the actual differential pressure (or pressure in port A - depending on the settings) as shown below;

  • The open area of ​​the valve is specified in a table and is dependent on the actual pressure difference between the ports (or the pressure in port A), while intermediate values ​​are calculated using interpolation;

  • The volumetric flow rate of liquid through the valve is specified in a table and is dependent on the actual pressure difference between the ports (pressure in port A), while intermediate values ​​are calculated using interpolation.

Opening area and pressure (for linear parameterization of area)

 Linear dependence of valve opening area (1) :

(1)#\[ A_{valve}=p_{norm} \cdot(A_{max}-A_{leak})+A_{leak}\]

Where normalized pressure (2) :

(2)#\[ p_{norm}=\frac{p_{control}-p_{cracking}}{p_{max}-p_{cracking}}\]

where:

 \(A_{max}\) - cross-sectional area of the valve in the fully open position, [m\(^2\)];

 \(A_{leak}\) - leakage area in fully closed valve position, [m\(^2\)].

Equation for mass flow rate

 Mass conservation principle (3):

(3)#\[ \dot m_{А}+\dot m_{B}=0\]

 Mass flow rate through valve (4):

(4)#\[\dot m = \frac{C_{d}\cdot A_{valve}\cdot \sqrt{2\cdot \bar\rho}}{\sqrt{PR_{loss}\cdot (1-(\frac{А_{valve}}{А_{port}})^2)}}\cdot \frac{\Delta p}{(\Delta p^2+ \Delta p_{crit}^2)^{1/4}}\]

where:

 \(C_{d}\) – pressure recovery loss factor;

 \(A_{valve}\) - valve flow area, [m\(^2\)];

 \(А_{port}\) - flow cross-section area, [m\(^2\)];

 \(\bar ho\) - average density of liquid, [kg/m\(^3\)];

 \(\Delta p\) – pressure differential across the valve, [Pa].

 Critical pressure differential \(\Delta p_{crit}\) - pressure differential associated with the critical Reynolds number, the point of flow mode change from laminar to turbulent (5):

(5)#\[ \Delta p_{crit}=\frac{\pi \cdot \bar \rho}{8 \cdot A_{valve}} \cdot (\frac {\nu \cdot Re_{crit}}{C_{d}} )^2\]

 The pressure loss describes the pressure differential in the valve as the flow area decreases.

 \(PR_{loss}\) calculated by the following formula (6):

(6)#\[ PR_{loss}=\frac {\sqrt {1-(\frac {A_{valve}}{A_{port}})^2 \cdot (1-C_{d}^2)}-C_{d} \cdot \frac {A_{valve}}{A_{port}}}{\sqrt {1-(\frac {A_{valve}}{A_{port}})^2 \cdot (1-C_{d}^2)}+C_{d} \cdot \frac {A_{valve}}{A_{port}}}\]

 Pressure recovery describes the positive pressure change in the valve as the area increases.

1.  Properties#

Property

Default value

Description

Units of measurement

Opening parametrization:
Linear;
Tab (areaVSpd);
Tab (flowVSpd)

Linear

-

-

Opening pressure specification:
DifPressure;
Pressure at port A,
available when Opening parametrization - Linear

DifPressure

-

-

Cracking pressure drop,
available when Opening parametrization - Linear, Opening pressure specification - DifPressure

1e4

-

Pa

Full open pressure drop,
available when Opening parametrization - Linear, Opening pressure specification - DifPressure

2e4

-

Pa

Cracking pressure at port,
available when Opening parametrization - Linear, Opening pressure specification - Pressure at port A

1e5

-

Pa

Full open pressure at port,
available when Opening parametrization - Linear, Opening pressure specification - Pressure at port A

2e5

-

Pa

Maximum valve cross area,
available when Opening parametrization - Linear

1.0E-4

-

m\(^2\)

Leakage area,
available when Opening parametrization - Linear

1.0E-10

-

m\(^2\)

Port cross area,
available when Opening parametrization - Linear

0.1

-

m\(^2\)

Discharge coefficien

0.64

-

-

Critical Reynolds number

150.0

The Reynolds number at which the transition from a laminar flow regime to a turbulent one occurs

-

Ptessure drop vector,
available when Opening parametrization - Tab (areaVSpd)

1e4;2e4;3e4;4e4;5e4;6e4;7e4;8e4;9e4;1e5

-

Pa

Area vector,
available when Opening parametrization - Tab (areaVSpd) or Tab (flowVSpd)

1.0E-10; 1.0E-5; 2.0E-5; 3.0E-5; 4.0E-5; 5.0E-5; 6.0E-5; 7.5E-5; 8.5E-5; 1.0E-4

-

m\(^2\)

Mass flow vector,
available when Opening parametrization - Tab (flowVSpd)

0.000358;0.045;0.11;0.191;
0.284;0.39;0.505;0.63;0.764;0.905

-

kg/s

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Isothermal hydraulics

Output

Output

-

-

Isothermal hydraulics