Flow resistance (IH)#
Block appearance in REPEAT VISION#
The Flow resistance (IH) block simulates the pressure drop in the isothermal hydraulic network section based on the specified nominal operating conditions.
Law of conservation of mass(1):
where:
\(\dot m_A\) – mass flow at the inlet, [kg/s];
\(\dot m_B\) – mass flow at the outlet, [kg/s].
Differential pressure
The differential pressure is determined according to the following formula (2):
where:
K – proportionality factor, [\(\frac{Pa \cdot s^2}{kg^2}\)];
\(\dot m\) – mass flow rate, [kg/s];
\(\dot m_{frc}\) – mass flow rate of transition to laminar flow mode, [kg/s].
The proportionality factor is calculated from the nominal values specified by user (3):
where:
\(\Delta p_{nom}\) – nominal differential pressure, [Pa];
\(\dot m_{nom}\) – nominal mass flow rate, [kg/s].
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Nominal pressure drop |
0.002 |
- |
MPa |
Nominal mass flow rate |
0.2 |
- |
kg/s |
Fraction of nominal mass flow rate for laminar flow mode |
0.001 |
- |
- |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Isothermal hydraulics |
Output |
Output |
- |
- |
Isothermal hydraulics |
In order to see the connection capabilities of the block, you need to go to page Description of block ports