GTU#

block

Block appearance in REPEAT VISION#

 Gas turbine units (GTU) are energy systems that convert the energy of compressed and heated gas into mechanical work and are used to generate electricity and heat.

1.  Properties#

Property

Default Value

Description

Units of measurement

Upper limit of dead zone (0-1)

0.02

–

–

Lower limit of dead zone (-1-0)

-0.02

–

–

Speed ​​controller gain

20

–

–

Time constant of the controller

0.1

–

s

Servomotor closing speed

1

–

r.u./s

Servomotor opening speed

1

–

r.u./s

Integrator gain, 1/Tsv (Servomotor time constant)

5

–

–

Combustion chamber time constant

2

–

s

Nominal power

1200

–

MW

Gain of the integrating link 1/Tjj (Inertial constant of the gas generator)

1/15

–

–

Share of gas generator power

0.6

–

r.u.

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Speed ​​setpoint

Input

–

r.u.

Automation

Current speed

Input

–

r.u.

Automation

Power setting

Input

–

r.u.

Automation

Power

Output

–

r.u.

Automation

Power

Output

–

W

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports