Power circuit breaker#
Block appearance in REPEAT VISION#
The Power circuit breaker block is designed to perform switching operations in the simulated electrical system.
The block can be either an ideal key or have its own active and inductive resistance.
The corresponding switchsets the initial state of the switch in the block properties: closed or open.Moreover, the state of the circuit breaker can be changed in thecourse of the calculation by control signals, for example, from the blocksof the Automation section. In this case, the logic for controlling the switch is as follows:
if Input 1 and Input 2 receive signals with a value equal to or greaterthan 1, the switch is open;
if condition 1 is not met and a signal equal to orgreater than 1 is sent to Input 1, the switch is closed;
greater than 1 is sent to Input 2, the switch is open
1. Properties#
Property |
Default value |
Description |
Units of measurement |
|---|---|---|---|
Initial position - closed |
On |
- |
- |
Incorporate the breaker impedance |
Off |
- |
- |
Circuit breaker resistance |
3.5 |
- |
Ohm |
Circuit breaker reactance |
2 |
- |
Ohm |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input 1 |
Input |
- |
- |
Elecrocity |
Input 2 |
Input |
- |
- |
Automation |
Input 3 |
Input |
- |
- |
Automation |
Current |
Output |
- |
А |
Elecrocity |
In order to see the connection capabilities of the block, you need to go to page Description of block ports