Power circuit breaker#

block

Block appearance in REPEAT VISION#

 The Power circuit breaker block is designed to perform switching operations in the simulated electrical system.

 The block can be either an ideal key or have its own active and inductive resistance.

 The corresponding switchsets the initial state of the switch in the block properties: closed or open.Moreover, the state of the circuit breaker can be changed in thecourse of the calculation by control signals, for example, from the blocksof the Automation section. In this case, the logic for controlling the switch is as follows:

  • if Input 1 and Input 2 receive signals with a value equal to or greaterthan 1, the switch is open;

  • if condition 1 is not met and a signal equal to orgreater than 1 is sent to Input 1, the switch is closed;

  • greater than 1 is sent to Input 2, the switch is open

1.  Properties#

Property

Default value

Description

Units of measurement

Initial position - closed

On

-

-

Incorporate the breaker impedance

Off

-

-

Circuit breaker resistance

3.5

-

Ohm

Circuit breaker reactance

2

-

Ohm

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input 1

Input

-

-

Elecrocity

Input 2

Input

-

-

Automation

Input 3

Input

-

-

Automation

Current

Output

-

А

Elecrocity

In order to see the connection capabilities of the block, you need to go to page Description of block ports