Ideal pressure source (TL)#

block

Block appearance in REPEAT VISION#

 The Ideal pressure source (TL) block models the pressure drop (additional pressure) between its ports, independent of the fluid flow rate.

 If the user indicates a negative differential value, the unit simulates additional losses in the area, while its main difference from any types of local resistances remains the independence of the value of this difference from the flow rate.

Note

This block is not a source of fluid flow — if the schematic lacks Reservoir (TL) blocks at the beginning and end of the hydraulic section (a closed loop section can use a single reservoir serving as both the start and end simultaneously), the model will not start the calculation.

 The user can specify the pressure drop in two ways, depending on the selected value of the Source type property:

  • When selecting the Constant value — using the Pressure property;

  • When selecting the Variable value — by supplying the current required pressure drop value via the automation port at any time.

1.  Properties#

Property

Default Value

Description

Units of measurement

Source type:
Variable;
Constant

Variable

-

-

Pressure, available when selecting Source type - Constant

30000.0

-

Pa

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Thermohydraulics

Pressure

Input

Available, when Source type - Variable

Pa

Automation

Output

Output

-

-

Thermohydraulics

In order to see the connection capabilities of the block, you need to go to page Description of block ports