Reservoir (TPF)#
Block appearance in REPEAT VISION#
The Reservoir (TPF) block models a tank of infinite volume with a given constant value of excess pressure and temperature (specific internal energy).
The user can select the method for specifying the energy of the medium in the tank through the Medium energy specification field.
In controlled mode, the energy and pressure parameters can change their values during the calculation process and are set by sending a signal to the corresponding ports of the block.
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Off |
- |
- |
|
Medium energy specification: |
Specific internal energy |
- |
- |
Gauge pressure |
30000.0 |
- |
Pa |
Specific internal energy, available when |
83881.0 |
- |
J/kg |
Temperature, available when [Medium energy specification`](#title2) - `Temperature` |
20.0 |
- |
°C |
Ports cross-sectional area |
0.2 |
- |
m\(^2\) |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Two-phase fluid |
Gauge pressure |
Input |
Available when |
Pa |
Automation |
Fluid energy specification |
Input |
Available when |
- |
Automation |
Output |
Output |
- |
- |
Two-phase fluid |
In order to see the connection capabilities of the block, you need to go to page Description of block ports