Tank (IH)#
Block appearance in REPEAT VISION#
The Tank (IH) block simulates a tank with a variable volume of fluids. The pressure above the fluid surface can be set to the atmospheric one (opened tank) or user pressure using the appropriate block property.
Hint
The user can select from 1 to 6 input ports through which the coolant flows.
The thermal resistance between the thermal port and the internal part of the tank is negligible and the temperature inside is equal to the temperature in the thermal port.
Important
When the level in the tank drops below the level of the cut-in, the calculation is completed with an error.
1. Mass balance
Mass conservation law (1) :
where:
\(\dot M\) - change of fluid mass in the tank, [kg/s];
\(\dot m_1, \dot m_2, \dot m_3, \dot m_4, \dot m_5, \dot m_6\) - mass flow rates through input ports, [kg/s].
2. Pulse balance (2) :
where:
\(p_i\) - pressure of the i-th input port, [Pa];
\(p_{дин}\) - dynamic pressure, [Pa];
\(p_б\) - pressure above the fluid surface, [Pa];
\(\rho\) - fluid density, [kg/m\(^3\)];
g - gravity factor, [m/s\(^2\)];
h - fluid level in the tank, [m];
h\(_i\) - cut-in level, [m].
Dynamic pressure (3) :
3. Medium volume in the tank
The medium volume in the tank is calculated based on the mass and density at each calculation step according to the following formula (4) :
where:
M - medium mass in the tank, [kg];
V - medium volume, [м\(^3\)].
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Number of ports: |
1 |
- |
- |
Pressurization specification: |
Atmospheric_pressure |
- |
- |
tankPressurization, available when selecting |
0.0 |
- |
MPa |
tankCrossSectionalArea |
1.0 |
- |
m\(^2\) |
inletHeight, available when selecting |
0.1 |
- |
m |
inletCrossSectionalArea, available when selecting |
0.01 |
- |
m\(^2\) |
inletsHeightVector, available when selecting |
0.1; 0.2 |
- |
m |
inletsCrossSectionalAreaVector, available when selecting |
0.01; 0.01 |
- |
m\(^2\) |
gravitationalAcceleration |
9.81 |
- |
m/s\(^2\) |
initialTankLevel |
3.0 |
- |
m |
2. Inputs and outputs#
Parameters |
Input/output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
From 1 to 6, depending on the choice of property - |
- |
Isothermal Hydraulics |