Pump (MF)#
Block appearance in REPEAT VISION#
The Pump (MF) block simulates the operation of a pump according to specified characteristics.
Law of conservation of mass (1) :
where:
\(\dot m_1\) – mass flow rate of the medium at the inlet, [kg/s];
\(\dot m_2\) – mass flow rate of the medium at the outlet, [kg/s].
Law of conservation of energy (2) :
where:
\(\phi_1\) – energy flow at the input, [W];
\(\phi_2\) – output energy flow, [W];
\(P_{гидр}=\frac{\dot m \cdot \Delta h_{из}}{\eta}\);
\(\dot m\) – mass flow rate of the medium, [kg/s];
\(\Delta h_{iz}\) – isentropic increase in enthalpy [J/kg];
\(\eta\) – Efficiency.
Calculation of pump head (3) :
where:
\(\Delta P\) – pressure increase, [Pa];
\(g\) – acceleration of gravity, [m/s\(^2\)];
\(\rho\) – density of the medium, [kg/m\(^3\)].
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Pump speed |
1000.0 |
- |
rev/min |
Pump speed curve |
1000.0;1500.0;2000.0; |
- |
rev/min |
Pump flow rate curves |
<10.0;20.0;30.0;40.0;50.0;60.0> |
- |
m\(^3\)/h |
Pump head curves |
<120.0;118.0;115.0;110.0;103.0;94.0> |
- |
m |
Pump efficiency curves |
<65.0;72.0;78.0;82.0;80.0;74.0> |
- |
% |
Reference density |
998.0 |
- |
kg/m\(^3\) |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Multicomponent fluid |
Output |
Output |
- |
- |
Multicomponent fluid |
In order to see the connection capabilities of the block, you need to go to page Description of block ports