Dead Zone Dynamic#

block

Block appearance in REPEAT VISION#

The Dead Zone Dynamic block generates a signal with bounds in a given area called the deadband.

Note

The lower boundary (LB) of signal and the upper boundary (UB) of signal are specified by the input ports as the Start of Deadband and End of Deadband parameters.

Note

The block output depends on the input (Signal) and values of boundaries.

Input

Output

LB \( \leq\) Signal \(\leq\) UB

Zero

Signal \(\geq \) UB

Signal – UB

Signal \(\leq\) LB

Signal – LB

1.  Properties#

No

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Upper Limit

Input

Input signal

-

Automation

Input

Input

Input signal

-

Automation

Lower Limit

Input

Input signal

-

Automation

Output

Output

Output signal

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports

3.  Code generation#

Important

Block supports C source code generation