Valve (MF)#

block

Block appearance in REPEAT VISION#

 The Valve (MF) block models shut-off and control valves in a pipeline system with a multi-component medium.

 Law of conservation of mass (1) :

(1)#\[\dot m_А+\dot m_В=0\]

where:

 \(\dot m_A\) – mass flow rate at the input, [kg/s];

 \(\dot m_В\) – mass flow rate at the outlet, [kg/s].

 Law of conservation of energy (2) :

(2)#\[\phi_А + \phi_В=0\]

where:

 \(\phi_А\) – energy flow at the input, [W];

 \(\phi_B\) – output energy flow, [W].

 Pressure drop: (3) :

(3)#\[\Delta P=(\frac{Q}{K_v})^2\]

where:

 \(\Delta P\) – pressure drop across the valve, [bar];

 \(Q\) – volume flow, [m\(^3\)/h];

 \(K_v\) – flow capacity coefficient, [m\(^3\)/h], (4) :

(4)#\[K_v=0.865 \cdot C_v\]

where \(C_v\) is the flow capacity coefficient, [m\(^3\)/h].

 The unit provides 3 modes for calculating the output pressure:

  • According to the outlet pressure (5):

(5)#\[P_{вых}=P_{зад}\]

where:

 \(P_{out}\) – pressure at the valve outlet, [Pa];

 \(P_{set}\) – pressure specified by the user as output, [Pa].

  • By opening percentage and \(K_v\) (6) :

(6)#\[P_{вых}=P_{вх}-(\frac{Q}{Kv_{effective}})^2\]

where:

 \(P_{out}\) – pressure at the valve outlet, [bar];

 \(P_{zad}\) – pressure at the valve inlet, [bar];

 \(Q\) – volume flow, [m\(^3\)/h];

 \(Kv_{effective}\) – effective flow coefficient, [m\(^3\)/h], (7) :

(7)#\[Kv_{effective}=Kv_{max} \cdot \frac{О}{100}\]

where:

 \(Kv_{max}\) – flow coefficient calculated as the volumetric flow rate of water at \(\rho\)=1000 [kg/m\(^3\)], which passes through the valve with a pressure drop of 1 [bar];

 \(О\) – percentage of opening of shut-off valves, %.

  • By opening percentage and \(C_v\) (8) :

(8)#\[P_{вых}=P_{вх}-(\frac{Q}{Cv_{effective}})^2\]

where:

 \(P_{out}\) – pressure at the valve outlet, [bar];

 \(P_{zad}\) – pressure at the valve inlet, [bar];

 \(Q\) – volume flow, [m\(^3\)/h];

 \(Сv_{effective}\) – effective flow coefficient, [m\(^3\)/h], (9) :

(9)#\[Сv_{effective}=Сv_{max} \cdot \frac{О}{100}\]

where:

 \(Сv_{max}\) – flow capacity coefficient, calculated as the volumetric flow rate of water at \(\rho\)=1000 [kg/m\(^3\)], which passes through the valve with a pressure drop of 1 [bar];

 \(О\) – percentage of opening of shut-off valves, %.

1.  Properties#

Property

Default Value

Description

Units of measurement

Valve calculation:
By outlet pressure;
By valve opening and K\(_v\);
By valve opening and C\(_v\)

By outlet pressure

-

-

Outlet pressure

200000.0

Available, when Valve calculation - Outlet pressure

Pa

Percentage of valve opening

100.0

Available, when Valve calculation - By valve opening and K\(_v\) or By valve opening and C\(_v\)

%

Flow factor C\(_v\)

280.0

Available, when Valve calculation - By valve opening and C\(_v\)

м\(^3\)/ч

Flow factor K\(_v\)

280.0

Available, when Valve calculation - By valve opening and K\(_v\)

м\(^3\)/ч

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Multicomponent fluid

Output

Output

-

-

Multicomponent fluid

In order to see the connection capabilities of the block, you need to go to page Description of block ports