Controlled load#
Block appearance in REPEAT VISION#
The Controlled load unit implements a mathematical model of static load, which is an electrical load, in calculations represented by a constant shunt resistance (which is a branch with series active and inductive reactive resistances), which value is calculated by the following formula (1) :
where:
U\(_{rat}\) - rated load voltage, [V];
P\(_{rat}\) - rated active power consumed by the load, [MW];
Q\(_{rat}\) - rated reactive power consumed by the load, [MVAr].
Parameters of rated active and reactive powers are set using Automation blocks.
1. Properties#
Property |
Default value |
Description |
Units of measurement |
|---|---|---|---|
Nominal active power |
1.0 |
- |
MW |
Nominal reactive power |
0.0 |
- |
Mvar |
Rated voltage |
10.0 |
- |
kV |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Rated voltage |
Input |
- |
kV |
Electrocity |
Active power |
Input |
- |
MW |
Automation |
Reactive power |
Input |
- |
Mvar |
Automation |
In order to see the connection capabilities of the block, you need to go to page Description of block ports