Controlled load#

block

Block appearance in REPEAT VISION#

 The Controlled load unit implements a mathematical model of static load, which is an electrical load, in calculations represented by a constant shunt resistance (which is a branch with series active and inductive reactive resistances), which value is calculated by the following formula (1) :

(1)#\[Z=R+j\cdot X= \frac{U_{ном}^2}{S_{ном}}\cdot cos \phi_{ном}+j\cdot \frac{U_{ном}^2}{S_{ном}}\cdot sin \phi_{ном}= \frac{U_{ном}^2 \cdot P_{ном}}{S_{ном}^2}+ j \cdot \frac{U_{ном}^2 \cdot Q_{ном}}{S_{ном}^2}\]

where:

 U\(_{rat}\) - rated load voltage, [V];

 P\(_{rat}\) - rated active power consumed by the load, [MW];

 Q\(_{rat}\) - rated reactive power consumed by the load, [MVAr].

 Parameters of rated active and reactive powers are set using Automation blocks.

1.  Properties#

Property

Default value

Description

Units of measurement

Nominal active power

1.0

-

MW

Nominal reactive power

0.0

-

Mvar

Rated voltage

10.0

-

kV

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Rated voltage

Input

-

kV

Electrocity

Active power

Input

-

MW

Automation

Reactive power

Input

-

Mvar

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports