Dead Zone#

block

Block appearance in REPEAT VISION#

 The Dead Zone block generates a signal with bounds in a given area called the deadband.

Note

The lower boundary (LB) of signal and the upper boundary (UB) of signal are specified as the parameters Start of Deadband and End of Deadband.

Note

The block output depends on the input (Signal) and values of boundaries.

Input

Output

LB \( \leq\) Signal \(\leq\) UB

Zero

Signal \(\geq \) UB

Signal – UB

Signal \(\leq\) LB

Signal – LB

1.  Properties#

Property

Default Value

Description

Units of measurement

Lower Limit

-1

-

-

Upper Limit

1

-

-

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Automation

Output

Output

-

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports

3.  Code generation#

Important

Block supports C source code generation