Mode LED#

block

Block appearance in REPEAT VISION#

 The Mode LED block represents a model of a physical LED that lights up for a given period of time.

Note

In the block properties, the Lower limit range and the Upper limit range are configured, within which the LED is in the enabled state (state of logical 1), as soon as the input signal is outside the specified range, the LED turns off (state of logical 0) (1) :

(1)#\[\begin{split}y(t) =\begin{cases}1 , & \ y_{min}<x<y_{max}\\0, & n, & y_{min}\geq x\\0,& x,&x\geq y_{max} \end{cases}\end{split}\]

where:

 \(y_{min}\) - lower boundary;

 \(y_{max}\) - upper boundary.

1.  Properties#

Property

Default Value

Description

Units of measurement

Lower limit range

2

-

-

Upper limit range

10

-

-

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input signal

Input

-

-

Automation

Output

Output

-

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports