Limiter Dynamic#

block

Block appearance in REPEAT VISION#

The Limiter Dynamic block limits the input signal by the following equation (1):

(1)#\[\begin{split} y\left(t\right) =\begin{cases}x , & \ ~ {\ y}_{min}<x<y_{max}\\{y}_{min} , &\ {\ y}_{min}\geq x \\y_{max} , & x\geq y_{max}\end{cases} \end{split}\]

where:

 \({y}_{min}\) – lower boundary (LB);

 \(y_{max}\) – upper boundary (UB).

1.  Properties#

No

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Upper bound

Input

-

-

Automation

Input

Input

-

-

Automation

Lower bound

Input

-

-

Automation

Output

Output

-

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports

3.  Code generation#

Important

Block supports C source code generation