Absorber (MF)#
Block appearance in REPEAT VISION#
The Absorber (MF) block models the process of absorption of a multicomponent medium.
Mass Conservation Law (1) :
where:
\(\dot m_A\) – mass flow rate at the inlet, [kg/s];
\(\dot m_B\) – mass flow rate at the outlet, [kg/s].
Law of conservation of energy (2) :
where:
\(\phi_A\) - energy flow at the input, [W];
\(\phi_B\) - energy flow at the output, [W].
Kremser equation for calculating absorption efficiency (3) :
where:
\(x_1\) – final concentration of the component in the liquid (at the outlet of the absorber);
\(x_2\) – initial concentration of the component in the liquid (at the entrance to the absorber);
\(x_0\) – equilibrium concentration;
\(N\) – number of theoretical plates;
\(A\) – absorption factor (4) :
where \(K\) is the Absorption efficiency coefficient.
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
0.9 |
- |
- |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Gas inlet |
Input |
- |
- |
Multicomponent fluid |
Liquid inlet |
Input |
- |
- |
Multicomponent fluid |
Gas outlet |
Output |
- |
- |
Multicomponent fluid |
Liquid outlet |
Output |
- |
- |
Multicomponent fluid |
In order to see the connection capabilities of the block, you need to go to page Description of block ports