Check Static Upper Bound#
Block appearance in REPEAT VISION#
The block of Check Static Upper Bound block checks whether the input reference signal is upper than the specified lower boundary at each time step and performs an assertion after the comparison. If the boundary is more than the input signal, the statement is true (1) and the block performs nothing. If not, the block stops the simulation and returns a default error message.
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Enabled check |
On |
Block accounting when calculating |
- |
Availibility of calculation stop |
On |
Stops calculation in case of check error |
- |
Off |
Responsible for output port visibility |
- |
|
Upper bound |
0 |
Bound |
- |
Include upper bound |
On |
Boundary accounting when comparing |
- |
Message when assertion fails |
error |
Check error response message |
- |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Automation |
Output |
Output |
Available when property |
- |
Automation |
In order to see the connection capabilities of the block, you need to go to page Description of block ports
3. Code generation#
Important
Block supports C source code generation