Check Static Range#

block

Block appearance in REPEAT VISION#

 The Check Static Range block checks that the input signal is more than (or possibly equal to) the static lower boundary or less than (or possibly equal to) the static upper boundary at the current time step. The Upper bound and Lower bound parameters define the upper and lower gap boundaries. The block then performs an assertion after the comparison. If the signal goes beyond the gap, the statement is true (1) and the block performs nothing.

1.  Properties#

Property

Default Value

Description

Units of measurement

Enabled check

On

Block accounting when calculating

-

Availibility of calculation stop

On

Stops calculation in case of check error

-

Availibility of output port

Off

Responsible for output port visibility

-

Upper bound

1

Upper range boundary

-

Lower bound

0

Lower range boundary

-

Include upper bound in range

On

Boundary accounting when comparing

-

Include lower bound in range

On

Boundary accounting when comparing

-

Message when assertion fails

error

Check error response message

-

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Automation

Output

Output

Available when property Availability of output port - On

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports

3.  Code generation#

Important

Block supports C source code generation