Expander (MF)#

block

Block appearance in REPEAT VISION#

 The Expander (MF) block models the expansion of a multicomponent mixture flow.

 Law of conservation of mass (1) :

(1)#\[\dot m_А+\dot m_В=0\]

where:

 \(\dot m_A\) – mass flow rate at the input, [kg/s];

 \(\dot m_В\) – mass flow rate at the outlet, [kg/s].

 Law of conservation of energy (2) :

(2)#\[\phi_А + \phi_В-P=0\]

where:

 \(\phi_А\) – energy flow at the input, [W];

 \(\phi_B\) – output energy flow, [W];

 \(P\) – power transmitted by the flow of the medium, [W].

 Polytropic power (3) :

(3)#\[W_{политроп}=\dot m \cdot (-\Delta H)\cdot \eta_{политроп}\]

where:

 \(\dot m\) – mass flow rate, [kg/s];

 \(\Delta H\) – change in enthalpy, [W];

 \(\eta_{polytrope}\) – polytropic Efficiency.

 Outlet pressure (4) :

(4)#\[P_{вых}=P_{зад}\]

where:

 \(P_{out}\) – pressure at the outlet of the expander, [Pa];

 \(P_{set}\) – pressure specified by the user as output, [Pa].

1.  Properties#

Property

Default Value

Description

Units of measurement

Outlet pressure

200000.0

-

Pa

Polytropic efficiency

0.9

-

-

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Multicomponent fluid

Output

Output

-

-

Multicomponent fluid

In order to see the connection capabilities of the block, you need to go to page Description of block ports