PWM generator (DC-DC)#

block

Block appearance in REPEAT VISION#

 A PWM generator (DC-DC) generates control signals depending on the duty factor. The duty factor shall be between 0 and 1. Depending on the control method, it shall be specified in the unit property during internal control or supplied to the input port from an external signal during external control. This unit is designed to control step-up and step-down DC-DC converters.

1.  Properties#

Property

Default Value

Description

Units of measurement

Control method:
External;
Internal

External

-

-

Frequency

10000.0

-

Hz

Duty cycle, available when Control mode - Internal

0.5

-

-

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Duty cycle

Input

Available when Control mode - External

-

Automation

Control signal

Output

-

-

Automation

In order to see the connection capabilities of the block, you need to go to page Description of block ports

3.  Code generation#

Important

Block supports C source code generation