Heat exchanger (double-pipe) (MF)#

block

Block appearance in REPEAT VISION#

 The Heat exchanger (double-pipe) (MF) block models the process of heat exchange between two media separated by a wall.

 Law of conservation of mass (1) :

(1)#\[\dot m_А+\dot m_В=0\]

where:

 \(\dot m_A\) – mass flow rate at the input, [kg/s];

 \(\dot m_В\) – mass flow rate at the outlet, [kg/s].

 Law of conservation of energy (2) :

(2)#\[\phi_А + \phi_В+Q=0\]

where:

 \(\phi_А\) – energy flow at the input, [W];

 \(\phi_B\) – output energy flow, [W];

 \(Q\) – heat flow through the wall, [W].

 Number of Transfer Units (NTU) (3) :

(3)#\[NTU=\frac{UA}{C_{min}}\]

where:

 \(UA\) – overall heat transfer coefficient, [W/K];

 \(C_{min}\) – minimum heat capacity of the flow, [W/K].

1.  Properties#

Property

Default Value

Description

Units of measurement

Overall heat transfer coefficient

350.0

-

W/(m² ·°C)

Heat transfer area

10.0

-

m²

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Liquid 1 inlet

Input

-

-

Multicomponent fluid

Liquid 2 inlet

Input

-

-

Multicomponent fluid

Liquid 1 outlet

Output

-

-

Multicomponent fluid

Liquid 2 outlet

Output

-

-

Multicomponent fluid

In order to see the connection capabilities of the block, you need to go to page Description of block ports