Solver properties#
Block appearance in REPEAT VISION#
The Solver properties block allows the user to specify solver parameters used when calculating the model.
If the model represents several unrelated physical systems, the diagram can contain the corresponding number of solver configuration blocks for each system separately. However, the presence of this block is not mandatory - a system of differential equations for a physical system for which solver settings are not specified will be solved using the default settings.
To link a block with solver settings to a specific physical system in the model diagram, it is sufficient to link it to any block that is part of this system.
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Parent ID |
- |
Determines to which physical system in the diagram the specified properties of the solver belong |
- |
Parameter |
- |
- |
- |
On |
Applies automatic configuration of the integration step without user intervention |
- |
|
Ground electric nodes |
Off |
Allows you to take into account or not take into account the grounding of electronic components |
- |
Time step, available when selecting |
50.0 |
Sets the integration frequency |
ms |
Ground resistance |
1.0E10 |
Sets the value of resistance to current spreading in the ground |
- |
Absolute tolerance |
1.0E-6 |
Specifies the corresponding error when solving the differential equation |
- |
Relative tolerance |
1.0E-6 |
Specifies the corresponding error when solving the differential equation |
- |
Functional tolerance |
1.0E-6 |
Specifies the corresponding error when solving the differential equation |
- |
Integration method: |
Backward Euler |
Allows the user to select a method for solving implicit differential equations - the backward Euler method (the value of the |
- |
2. Inputs and outputs#