Average-value three-phase bridge converter#
Block appearance in REPEAT VISION#
The unit uses a voltage source directly controlled by the reference voltage to simulate the converter. The model does not require a PWM generator and does not simulate the rectifier mode. For control, it is necessary to create a vectorized signal to control the converter. The signal shall contain three reference voltages (one for each phase).
1. Properties#
Property |
Default value |
Description |
Units of measurement |
|---|---|---|---|
Snubber resistance on DC side |
10000.0 |
– |
Ohm |
Resistance of each phase on AC side |
1.0 |
– |
Ohm |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Control |
Input |
- |
- |
Automation |
+ |
Input |
- |
- |
Electronics |
- |
Output |
- |
- |
Electronics |
А |
Output |
- |
- |
Electronics |
В |
Output |
- |
- |
Electronics |
С |
Output |
- |
- |
Electronics |
In order to see the connection capabilities of the block, you need to go to page Description of block ports