Four way two position valve (TL)#

block

Block appearance in REPEAT VISION#

 The block models the operation of a valve with four orifices in a thermal-hydraulic network. The valve is controlled by a single spool, the position of which is determined by the signal at port S. The block has two inlets — A and B and two outlets — P and T.

 When ports are paired (AP, BP, AT, and BT), the block models fluid flow through four different orifices. Parameters affecting the flow through each orifice (spool stroke and maximum flow area) can be set identically for all four orifices or individually. The user also sets the initial spool offset (Valve close position parameter) relative to the position where the orifice is fully open.

 The current spool displacement relative to its initial position is set by the signal through the automation port — at zero signal, all orifices are closed, and as the spool moves, they begin to open sequentially according to the orifice diameter and the specified offset. If the spool continues to move after the orifice is fully open (within the specified maximum stroke), saturation occurs, and the flow through the valve orifice does not increase.

 The flow area of each orifice depends linearly on the spool position and is described by the formula (1):

(1)#\[A_{orifice}=\frac{A_{max}-A_{leak}}{\Delta S}\cdot S_{pos} + A_{leak}\]

where:

 \(S_{pos}\) - calculated parameter based on the signal from the automation port Valve close position, [m];

 \(\Delta S\) - parameter Valve travel, [m];

 \(A_{max}\) - parameter Valve max area, [m\(^2\)];

 \(A_{leak}\) - parameter Leakage area, [m\(^2\)].

1.  Properties#

Property

Default Value

Description

Units of measurement

Positive spool position open connections:
All closed;
PA and BT;
PA and PB;
PB and AT;
PA;
PB;
All opened

PA and BT

-

-

Negative spool position open connections:
All closed;
PA and BT;
PA and PB;
PB and AT;
PA;
PB;
All opened

PA and BT

-

-

Characteristics for area:
Identical;
Different

Identical

-

-

Cross area calculation method:
Linear;
Tab

Linear

-

-

Valve travel PA

5e-3

Available, when Characteristics for area - Different

m

Valve travel PB

5e-3

Available, when Characteristics for area - Different

m

Valve travel AT

5e-3

Available, when Characteristics for area - Different

m

Valve travel BT

5e-3

Available, when Characteristics for area - Different

m

Valve max area PA

1e-4

Available, when Characteristics for area - Different

m\(^2\)

Valve max area PB

1e-4

Available, when Characteristics for area - Different

m\(^2\)

Valve max area AT

1e-4

Available, when Characteristics for area - Different

m\(^2\)

Valve max area BT

1e-4

Available, when Characteristics for area - Different

m\(^2\)

Valve travel

5e-3

Available, when Characteristics for area - Identical and Cross area calculation method - Linear

m

Valve max area

1e-4

Available, when Characteristics for area - Identical and Cross area calculation method - Linear

m\(^2\)

Leakage area

1e-10

Available, when Cross area calculation method - Linear

m\(^2\)

Area port

0.1

-

m\(^2\)

Reynolds critical numbers

150

-

-

Smoothing factor

0.01

Available, when Cross area calculation method - Linear

-

Pressure recovery

0.64

-

-

Valve close position PA

5e-3

-

m

Valve close position PB

5e-3

-

m

Valve close position AT

5e-3

-

m

Valve close position BT

5e-3

-

m

Spool position vector

0, 0.02, 0.04, 0.07, 0.017

Available, when Characteristics for area - Identical and Cross area calculation method - Tab

m

Valve cross area vector

1e-06, 1e-05, 1e-04, 1e-3, 3e-3

Available, when Characteristics for area - Identical and Cross area calculation method - Tab

m\(^2\)

Spool position vector PA

0, 0.02, 0.04, 0.07, 0.017

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m

Spool position vector PB

0, 0.02, 0.04, 0.07, 0.017

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m

Spool position vector AT

0, 0.02, 0.04, 0.07, 0.017

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m

Spool position vector BT

0, 0.02, 0.04, 0.07, 0.017

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m

Valve cross area vector PA

1e-06, 1e-05, 1e-04, 1e-3, 3e-3

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m\(^2\)

Valve cross area vector PB

1e-06, 1e-05, 1e-04, 1e-3, 3e-3

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m\(^2\)

Valve cross area vector AT

1e-06, 1e-05, 1e-04, 1e-3, 3e-3

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m\(^2\)

Valve cross area vector BT

1e-06, 1e-05, 1e-04, 1e-3, 3e-3

Available, when Characteristics for area - Different and Cross area calculation method - Tab

m\(^2\)

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Port A

Input

-

-

Thermohydraulics

Port B

Input

-

-

Thermohydraulics

Spool displacement

Input

-

m

Automation

Port P

Output

-

-

Thermohydraulics

Port T

Output

-

-

Thermohydraulics

In order to see the connection capabilities of the block, you need to go to page Description of block ports