Three-phase parallel RLC delta load#
Block appearance in REPEAT VISION#
The Three-phase parallel RLC delta load, block is a model of a three-phase parallel load triangle connected, with interphasecomponents connected in parallel.
The parameters of phase components (active resistance, inductance and capacity) are determined according to the given power based on the assumption of their parameters constancy.
Capacities can be set as three-phase (then each phase will consume thesame power and the load will be symmetrical) or in phase (then the load will be asymmetrical).
1. Properties#
Property |
Default value |
Description |
Units of measurement |
|---|---|---|---|
Branch type: |
RLC |
– |
– |
Off |
– |
– |
|
Nominal phase-to-phase voltage |
10e3 |
– |
V |
Nominal frequency |
50 |
– |
Hz |
Three-phase active power |
10e3 |
Available, when |
W |
Active powers of phases, available, when |
10e3;10e3;10e3 |
The format for completing: PA;PB;PC |
W |
Inductive powe |
10e3 |
Available, when |
VAr |
Inductive powers of phases, available, when |
10e3;10e3;10e3 |
The format for completing: QLA;QLB;QLC |
VAr |
Capacitive power |
10e3 |
Available, when |
VAr |
Capacitive powers of phases, available, when |
10e3;10e3;10e3 |
The format for completing: QCA;QCB;QCC |
VAr |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
A |
Input |
– |
– |
Electronics |
B |
Input |
– |
– |
Electronics |
C |
Input |
– |
– |
Electronics |
In order to see the connection capabilities of the block, you need to go to page Description of block ports