Compressor Tabulated Pump (P)#

block

Block appearance in REPEAT VISION#

simplified version of compressor without reference data and shaft angular velocity

 The block describes the compressor operation by characteristics.

 The block stores mass so that (1)

(1)#\[\dot m_A+\dot m_B=0\]

 Compressor mass flow rate is determined by characteristics of mass flow rate vector from pressure ratio vector.

 \(\dot m\) - gas mass flow rate, [kg/s].

Law of conservation of energy (2):

(2)#\[\phi_A+\phi_B+P_{fluid}=0\]

where \(P_{fluid}\)=\(\dot m_A \cdot \Delta h_{total}\)

 \(P_{fluid}\) - work on gas (flow rate for enthalpy change).

1.  Properties#

Property

Default Value

Description

Units of measurement

Port area

0.1

-

m\(^2\)

Mass flow vector

29.013; 28.747; 28.641; 28.412; 28.06; 27.098; 25.306

-

kg/s

Pressure ratio vector

4.841; 5.445; 5.988; 6.628; 7.222; 7.323; 7.573

-

dimensionless value

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

Input

Input

-

-

Pneumatics

Output

Output

-

-

Pneumatics

In order to see the connection capabilities of the block, you need to go to page Description of blocks ports