Compressor Tabulated Pump (P)#
Block appearance in REPEAT VISION#
simplified version of compressor without reference data and shaft angular velocity
The block describes the compressor operation by characteristics.
The block stores mass so that (1)
Compressor mass flow rate is determined by characteristics of mass flow rate vector from pressure ratio vector.
\(\dot m\) - gas mass flow rate, [kg/s].
Law of conservation of energy (2):
where \(P_{fluid}\)=\(\dot m_A \cdot \Delta h_{total}\)
\(P_{fluid}\) - work on gas (flow rate for enthalpy change).
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Port area |
0.1 |
- |
m\(^2\) |
Mass flow vector |
29.013; 28.747; 28.641; 28.412; 28.06; 27.098; 25.306 |
- |
kg/s |
Pressure ratio vector |
4.841; 5.445; 5.988; 6.628; 7.222; 7.323; 7.573 |
- |
dimensionless value |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Pneumatics |
Output |
Output |
- |
- |
Pneumatics |