Single-phase circuit parameters meter#

block

Block appearance in REPEAT VISION#

 The Single-phase circuit parameters meter unit is designed to obtain the following parameters of single-phase circuits:

  • instantaneous voltage value;

  • effective voltage value;

  • instantaneous current value;

  • effective current value

  • instantaneous active power;

  • average active power;

  • average reactive power;

  • average apparent power;

  • power factor.

 The internal resistance between the phase or neutral input and output terminals is zero. The internal resistance between the phase and neutral terminals is zero (infinity).

 The block eliminates the need to calculate the effective values ​​of currents and voltages, as well as average power values. This option is set in the parameters and can be used to save computing resources and speed up the simulation process.

 The parameters are calculated as follows:

  • The effective values ​​of voltage or current are determined by the formula (1):

(1)#\[X_{rms}=\frac{1}{T} \cdot \sqrt{\int^T_0x^2dt}\]

where:

 \(x\) – instantaneous value of the measured parameter (voltage u or phase current i);

 \(T\) – measurement period, which is determined by the formula (2):

(2)#\[T=\frac{1}{f}\]

where \(f\) is the base frequency, [Hz].

  • The instantaneous voltage value is determined by the formula (3):

(3)#\[u=\phi(L)-\phi(N)\]
  • Instantaneous current value i is defined as the magnitude of the electric current passing through the input and output terminals of the phase (L+; L–).

  • Instantaneous active power is determined by the formula (4):

(4)#\[p=u \cdot i\]
  • Average power values are determined based on the instantaneous power values ​​(5):

(5)#\[\begin{split}P=\frac{1}{T}\cdot \int^T_0pdt,\\S=\frac{P}{U_{rms \cdot I_{rms}}},\\Q=\sqrt{S^2-P^2}\end{split}\]
  • Power factor is determined by the formula (6) :

(6)#\[K_M=\frac{P}{S}\]

1.  Properties#

Property

Default Value

Description

Units of measurement

Base frequency

50

Determines the period for calculating root mean square and average values

Hz

Initial values of calculated values: \(U_{rms}\), \(I_{rms}\), \(P\), \(S\)

0, 0, 0, 0

Allows you to maintain the initial value at a given level during the calculation of average and root mean square values ​​at the beginning of the simulation

–

Calculation of root mean square values ​​of voltage and current, as well as average powers

On

Determines the period for calculating root mean square and average values

–

2.  Inputs and outputs#

Parameters

Input/Output

Description

Units of measurement

Port type

L+

Input

Phase input pin

–

Electronics

N+

Input

Zero input pin

–

Electronics

L-

Output

Output phase pin

–

Electronics

N-

Output

Output pin zero

–

Electronics

In order to see the connection capabilities of the block, you need to go to page Description of block ports