Farrow filter#
Block appearance in REPEAT VISION#
The Farrow filter block is designed to adjust the signal time using a fractional delay. It allows the signal value to be calculated at any intermediate point between real physical time samples without changing the sampling frequency.
The delay fraction specifies the shift value in the range from 0.0 to 1.0. It determines at what point between the previous and current samples the signal should be reconstructed.
The block’s operation is based on a cubic polynomial, which continuously describes the signal’s shape over time. To find the final signal value at a user-specified point d, the cubic equation (1) is solved:
Based on the latest signal samples (\(x_0\), \(x_1\), \(x_2\), \(x_3\)), the block calculates the basic geometric coefficients.
\(v_0 = x_1\) - base height (free term of the count);
\(v_1 = -\frac{x_0}{3} + x_1 -\frac{x_2}{2}-\frac{x_3}{6}\) - rate of change (signal slope);
\(v_2 = \frac{x_0}{2} - x_1 +\frac{x_2}{2}\) - signal acceleration (its bending);
\(v_3 = -\frac{x_0}{6} + \frac{x_1}{2}-\frac{x_2}{2} + \frac{x_3}{6}\) - curvature of a cubic spline.
1. Properties#
Property |
Default Value |
Description |
Units of measurement |
|---|---|---|---|
Delay fraction |
0.5 |
- |
- |
2. Inputs and outputs#
Parameters |
Input/Output |
Description |
Units of measurement |
Port type |
|---|---|---|---|---|
Input |
Input |
- |
- |
Automation |
Output |
Output |
- |
- |
Automation |
In order to see the connection capabilities of the block, you need to go to page Description of block ports